    Problem Report Number 0082
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0082
    Raised 1993-08-17 08:00
    Updated 2003-03-13 08:00
    Published 1993-08-19 08:00
    Product Standard XPG4 ISAM
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.2.4
    Test Identification dm.isam/ix/isdelindex 1
    Problem Summary TSD4.082 This test assumes that as user delete index, index number returned by isindexinfo will shift. For above test, old new key2 delete key3 key2 key4 key3 key5 key4 But X/Open isam specification does not m...
    Problem Text
    This test assumes that as user delete index, index number returned by
    isindexinfo will shift. For above test,

    old new
    key2 delete
    key3 key2
    key4 key3
    key5 key4

    But X/Open isam specification does not mention these index number's
    behavior. So we exchange these numbers as follows.

    old new
    key2 delete
    key3 key3
    key4 key4
    key5 key2

    Test Output
    /tset/dm.isam/ix/isdelindex/T.isdelindex 1 Failed

    Test Information:
    Failed: isindexinfo() gave wrong flag values for key 2
    Expected: 0x0 Observed: 0x1
    Failed: isindexinfo() gave wrong start position for key 2
    Expected: 4 Observed: 8
    Failed: isindexinfo() gave wrong start position for key 3
    Expected: 6 Observed: 4
    Failed: isindexinfo() gave wrong flag values for key 4
    Expected: 0x1 Observed: 0x0
    Failed: isindexinfo() gave wrong start position for key 4
    Expected: 8 Observed: 6

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    The ISAM specification states that the index numbers may vary after an
    index has been added or deleted. This indicates that the fault reported
    is a test suite deficiency and a waiver is recommended.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed test suite deficiency.