Problem Report 0063 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0063.


Report 0063 Actions


    Problem Report Number 0063
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0063
    Raised 1993-02-25 08:00
    Updated 2003-03-13 08:00
    Published 1993-03-12 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.2.4
    Test Identification POSIX.os/devclass/tcdrain 9
    Problem Summary TSD4.063 In test 9 (IXON/IXOFF) is cleared on the read side of the test (tty_fields). The subsequent write to the loop side (baudrate 38400) overfloads the read side with more than 34000 chars. When an impleme...
    Problem Text
    In test 9 (IXON/IXOFF) is cleared on the read side of the test (tty_fields).
    The subsequent write to the loop side (baudrate 38400) overfloads the read
    side with more than 34000 chars. When an implementation defined highwater
    mark is reached in the driver, the chars are discarded and therefore the
    test fails.
    Flow control should not be swiched off for the read side or the write should
    be delayed.
    Test Output
    Test Results:

    ************************************************************************
    /tset/POSIX.os/devclass/tcdrain/T.tcdrain 9 Unresolved

    Test Information:
    read() from VSX_TERMIOS_TTY failed
    when TOSTOP flag was set
    ************************************************************************


    Test Output:

    400|0 9 1 13:50:22|IC Start
    200|0 9 13:50:22|TP Start
    520|0 9 24693 2 1|read() from VSX_TERMIOS_TTY failed
    520|0 9 24666 3 1|when TOSTOP flag was set
    220|0 9 2 13:51:48|UNRESOLVED
    410|0 9 1 13:51:48|IC End

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    This is accepted as a Test Suite Deficiency in VSX 4.2.4 which seems to have
    been uncovered by use of the 38400 baud rate.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed Test Suite Deficiency.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority