Report 0029 Actions


    Problem Report Number 0029
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0029
    Raised 1992-09-18 08:00
    Updated 2003-03-13 08:00
    Published 1992-09-29 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.2.3
    Test Identification XOPEN.os/maths/y0 10
    Problem Summary TSD4.029 An identical error exists in y0 test 11. The fault in this case is caused by a floating point overflow in the test suite. The modus operandi of the suite is to call the funciton under test and then to...
    Problem Text

    An identical error exists in y0 test 11.

    The fault in this case is caused by a floating point overflow
    in the test suite. The modus operandi of the suite is to
    call the funciton under test and then to call its own function
    and to compare the results.

    In these two cases the test is checking overflow condition handling
    within the y0() library function. Unfortunately although
    our code returns -HUGE_VAL & sets errno to ERANGE the test still
    calls its own function which promptly overflows and core-dumps.

    The test code ought to skip the call of its own function in these
    two tests if overflow has been indicated by the library function
    to avoid this case.
    Test Output

    /tset/XOPEN.os/maths/y0/T.y0 10 Unresolved

    child process was terminated by signal 8 (SIGFPE)
    ******************************************************************

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    This is accepted as a test suite fault and a permanent waiver is recommended.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed Test Suite Deficiency.