HomeAbout Us A-Z IndexSearch * Contact Us Register LoginPress Shop

The Open Brand -- Problem Reporting and Interpretations System


Problem Report 0024 Details

Help Show help | Quick Search | Submit a Test Suite Support Request | Click here to view your privileges

This page provides all information on Problem Report 0024.


Report 0024 Actions


    Problem Report Number 0024
    Submitter's Classification Test Suite problem
    State Resolved
    Resolution Test Suite Deficiency (TSD)
    Problem Resolution ID TSD.X.0024
    Raised 1992-09-18 08:00
    Updated 2003-03-13 08:00
    Published 1992-09-29 08:00
    Product Standard Internationalised System Calls and Libraries (XPG4)
    Certification Program The Open Brand certification program
    Test Suite VSX4 version 4.2.3
    Test Identification XPG4.hdr/misc/float 4
    Problem Summary TSD4.024 (Ref. UniSoft: err.4.2.3.035) The expected values for certain constants seem to be up the creek. For example, FLT_RADIX which is 16 on our machine is expected to be 4. This seems to have a cascade eff...
    Problem Text

    (Ref. UniSoft: err.4.2.3.035)

    The expected values for certain constants seem to be up the creek.
    For example, FLT_RADIX which is 16 on our machine is expected to
    be 4. This seems to have a cascade effect through the following
    tests. I cannot offer any suggestions as to the exact cause of
    this bug in the suite.
    Test Output
    /tset/XPG4.hdr/misc/float/T.float 4 Failed

    Test Information:
    Feature test macros: -D_XOPEN_SOURCE
    Compiler or run-time messages or results:
    Value of FLT_RADIX is incorrect
    Observed: 16
    Expected: 4
    Value of FLT_MAX_EXP is incorrect
    Observed: 63
    Expected: 126
    Value of FLT_MIN_EXP is incorrect
    Observed: -64
    Expected: -129
    Value of FLT_MANT_DIG is incorrect
    Observed: 6
    Expected: 24
    Value of DBL_MAX_EXP is incorrect
    Observed: 63
    Expected: 126
    Value of DBL_MIN_EXP is incorrect
    Observed: -64
    Expected: -129
    Value of DBL_DIG is incorrect
    Observed: 15
    Expected: 16
    Value of DBL_MANT_DIG is incorrect
    Observed: 14
    Expected: 56
    Value of LDBL_MAX_EXP is incorrect
    Observed: 63
    Expected: 126
    Value of LDBL_MIN_EXP is incorrect
    Observed: -64
    Expected: -129
    Value of LDBL_DIG is incorrect
    Observed: 15
    Expected: 16
    TEST INFORMATION TRUNCATED BY -t OPTION
    ************************************************************************

    Review Information

    Review Type TSMA Review
    Start Date null
    Completed null
    Status Complete
    Review Recommendation No Resolution Given
    Review Response
    This is accepted as a test suite error and a permanent waiver is recommended.

    Review Type SA Review
    Start Date null
    Completed null
    Status Complete
    Review Resolution Test Suite Deficiency (TSD)
    Review Conclusion
    This is an agreed Test Suite Deficiency.

    Problem Reporting System Options:

     

    Back   


Contact the Certification Authority